DescriptionVCL-64HSL, 64 Port
E1, HSL (High Speed Signaling Link) Monitoring equipment is suitable for
"non-intrusive" monitoring application and for monitoring of upto 32,
"live" HSL E1 (High Speed Signaling Link) traffic links, bi-directionally (i.e.
in both transmit and receive directions).
Description
The VCL-64HSL, 64 Port E1, HSL (High Speed
Signaling Link) Monitoring Equipment is equipped with 64 E1 receive ports, through which
the "tapped / monitored" signal of the 32 "live" HSL E1 links" is
input from a high impedance (Hi-Z) point of a DDF / patch-panel. The equipment also
provides 64 E1 transmit (output) ports from where the regenerated and reproduced E1
"monitored" link output is obtained by the user to connect to protocol
analysers, test probes, billing servers etc. as a normal E1.
The VCL-64HSL, 64 Port E1, HSL (High Speed
Signaling Link) Monitoring Equipment is capable of monitoring a -20dBdsx (0.3 Volt Pulse)
input E1 signal through a Hi-Z path, without in any way affecting or disturbing the
"live" E1 traffic that is required to be monitored. The VCL-64HSL, 64 Port E1, HSL (High Speed Signaling Link) Monitoring Equipment, occupies
only a 2U high rack-space, and is a compact 19-inch stand-alone unit. The unit is powered
by and operates on a -48V DC power supply. An AC mains option is also available with an
external AC-DC converter.
|