Product Part Number
# 1 Option:
XC-1467-T1-48 (with -48V DC Power, 3U / 133mm, 19 Inch Rack Mount, RJ45 connectors)
Product Part Number # 2 Option:
XC-1468-T1-48
(with -48V DC Power, 2U / 90mm, 19 Inch Rack Mount, DB-37 connectors)
Application - Where is it used?
The XC 64 T1 electronic patch
panel is designed to be used in Central Offices, Data Centers,
Command and Control Centers, Remote Cell Sites, Utilities and Dealing Rooms seeking to
eliminate the jungle of external
patch-cords and loosely hanging wires which usually
exists in locations where patch panels
are installed.
Why it should be used?
Easier Management - The XC 64 T1 electronic patch panel allows
easier management of the cross-connects since all
cross-connects can be controlled and managed from a central
location over TCP/IP or UDP Network using either CLI (text)
commands, or a GUI or SNMP.
The XC 64 T1 electronic patch panel eliminates the use of patch
cords and the maze of loosely hanging inter-connect
wires.
Better Management - the XC 64 T1 electronic patch panel allows
better and more efficient management since a log of all
patches / cross-connects can be
archived as an MS (Microsoft) Access database files and retrieved
whenever required.
The XC 64 T1 electronic patch panel eliminates the need for
labelling the patch-cords and inter-connected wires since all
inter-connection records are
automatically retained in the system's non-volatile memory.
Additionally, the same can also be saved and archived as an MS
(Microsoft) Access database file from the system's GUI.
An Intelligent Patch Panel
The XC 64 Port T1 electronic patch panel keeps the
user informed of a potential problem by generating an alarm.
The XC 64 Port T1 electronic patch panel generates
SNMP V2 alarms and is supplied with an MIB file which allows the
user to easily integrate the XC 64 Port T1 Electronic Patch Panel
into their NMS (Network Management Software) for faster
trouble-shooting and fault rectification. This results in more
efficient network control and fault management.
The XC 64 Port T1 electronic patch panel also
maintains a log of the 200 most recent time-stamped events, as they
occur in real-time, by storing them in the system memory. These
events may be viewed at any time by a user. The system event log is
maintained in addition to SNMP V2 traps, which the equipment sends
out to a centralized NMS, when such events or alarms occur.
User friendly the equipment may be assessed remotely
using Telnet, GUI (Graphical User Interface) or SNMP over an
Ethernet link through the system's 10/100BaseT Ethernet Port. The
equipment may be also accessed locally through either an RS232 (DB9)
serial or a USB COM Port.
Additional Advantages
Automatic circuit protection and re-routing option
(available with optional software module).
The XC 64 Port T1 electronic patch panel provides the
user (optional software module) to re-route any T1 circuit to a
secondary route (secondary T1 Port) in the event of the failure of
the primary route (primary T1 port).
This feature ensures that critical T1 routes can be
automatically be protected on the cross-connect (in a “N”+1
protection scheme) and can be re-routed to secondary standby route(s)
in the event of the failure of the primary route without any
intervention of the maintenance staff. Such a feature is especially
useful at unmanned locations or at remote locations where the
maintenance staff may not be present at all times of the day to
provide immediate critical servicing, if required.
Highlights
-
64, T1 to T1 patch panel equipment
-
Intelligent electronic patch-panel allows the user
to cross-connect between any T1 port to any T1 port, or to
multiple T1 ports (broadcast mode only), electronically
-
Allows the user to re-route any T1 circuit to a
secondary route (secondary T1 Port) in the event of the failure of
the primary route (primary T1 port), without any human
intervention.
-
Hitless (automatic) switching between Primary T1
and Standby T1 links
-
Eliminates the use of the messy, loose, hanging
inter-connect wires
-
Host of alarms for trouble shooting and maintenance
-
SNMP - V2 Traps / Alarms
-
Telnet and GUI based remote management features
-
Dual power inputs (1+1) to connect the equipment to
two separate -
48V DC power sources for power source
redundancy.
Indications and Alarm Monitoring
-
Loss of incoming signal at any T1 Port
-
Configuration error alarm
-
64 LED indicators to indicate the status of each T1
link
-
System's internal 3 Volts power supply present
-
External -48V DC input present
-
System Self Test Error.
Programmable Features
-
Enabling or disabling T1 channels (masking) of the
T1 channels that are un-connected and not in use
-
Creating a cross connect between T1s using the
Windows based, easy to use GUI
-
Telnet interface for remote programming by using
text commands
-
SNMP - V2
Status Monitoring
-
Status of alarms
-
Enabled / Disabled status of T1 ports
-
Monitoring of the XC 64 Port T1 Electronic Patch
Panel status and configuration
-
SNMP - V2 Traps / Alarms.